NikMann Edgebander ALARM-04: Low Air Pressure
If your NikMann edgebander displays ALARM-04, the machine has detected that compressed-air pressure has fallen below its monitored threshold of 0.5 MPa (5 bar / approximately 72.5 PSI). Learn how to check the air supply, identify common causes and determine when professional technical support is needed.
Request Service Call 1300 4 FORZAWhat Does ALARM-04 Mean?
ALARM-04 indicates that the machine's compressed-air pressure monitoring system has detected pressure below the required threshold. The controller may stop machine operation to help prevent pneumatic components from operating incorrectly.
Compressed air is used by various pneumatic functions on an edgebander. Depending on the model and configuration, these can include cylinders, pressure mechanisms, trimming units, the guillotine and other machine movements.
The alarm identifies a low-pressure condition; it does not automatically mean that the pressure switch has failed. Check the actual air supply and machine pressure before replacing components.
Compressor Switched Off
The workshop compressor may be switched off, not running correctly or unable to supply air to the machine.
Insufficient Air Pressure
The compressor may not have built up enough pressure, or the supply pressure may drop when several machines operate at the same time.
Disconnected or Restricted Hose
A disconnected, kinked, damaged or restricted air hose can reduce the air reaching the edgebander.
Regulator Set Incorrectly
The machine's filter-regulator may be set below the specified working pressure. Check the gauge and machine documentation before making adjustments.
Air Leak
A leaking hose, fitting, valve or pneumatic component can cause the pressure to fall below the alarm threshold.
Pressure Switch or Sensor Fault
If the pressure is within specification but the alarm remains active, the pressure switch, sensor, wiring or control circuit may require testing.
Listen carefully for escaping air.
Inspect: Pneumatic fittings, Air tubing, Cylinders, Solenoid valves, FRL unit, Quick connectors.
Check the machine air regulator.
Adjust pressure between: 0.6–0.8 MPa. Drain water from the air filter. Clean or replace the filter element.
Reset ALARMS by pressing the button on a screen.
If your machine still have a problem , please call : 1300 4 FORZA
STEP-BY-STEP CHECKS
How to Troubleshoot ALARM-04
Stop the Machine Safely
Follow the machine's shutdown procedure. Keep clear of moving components and wait until all movement has stopped before carrying out checks.
Check the Compressor
Confirm that the compressor is running and its pressure gauge shows an adequate supply. Consider whether other connected equipment is consuming too much air.
Inspect the Machine Pressure Gauge
If fitted, check the filter-regulator gauge and compare the reading with the required working pressure specified in the manual for your particular NikMann model.
Check Hoses and Connections
Look for visible damage, disconnected hoses, kinks or obvious leaks. Do not disconnect pneumatic fittings while the system is pressurised.
Check for Pressure Drops
If pressure falls again when the machine operates, investigate possible leaks, restricted pipework, insufficient compressor capacity or pneumatic faults.
Reset Only After Correcting the Cause
Once the correct pressure has been restored and the cause addressed, follow the machine's normal alarm-reset procedure. If the alarm returns, arrange technical support.
Important Safety Information
Do not bypass the pressure switch or continue operating the machine while ALARM-04 remains active. Insufficient air pressure can prevent pneumatic components from completing their movements correctly.
Before disconnecting hoses, servicing regulators or working on pneumatic components, isolate the machine and release stored compressed-air pressure according to the manufacturer's procedure. Electrical inspection and pressure-switch testing should be performed by appropriately qualified personnel.
Always follow the operating and maintenance instructions for your exact machine model.
PREVENTATIVE MAINTENANCE
How to Reduce Future Air-Pressure Alarms
- Check compressor pressure and operation regularly.
- Ensure the compressor and pipework can meet the machine's air demand.
- Inspect accessible air hoses and fittings for damage or leaks.
- Maintain the filter-regulator assembly as specified by the manufacturer.
- Investigate recurring pressure drops instead of repeatedly resetting the alarm.
- Arrange regular machinery maintenance to identify developing faults.
FORZA MACHINERY
Technical Support for NikMann Edgebanders
Forza Machinery supplies woodworking machinery and provides technical support, servicing, repairs, maintenance and spare parts for professional woodworking businesses.
We don't just sell machines — we help keep your business running.
Machinery Experience
Practical woodworking machinery knowledge to help diagnose faults and minimise avoidable downtime.
Fault Diagnosis
Assistance with pneumatic issues, machine alarms, operating faults and technical troubleshooting.
Service and Repairs
Machinery servicing, maintenance, repairs and spare-parts support for woodworking equipment.
Australian Support
Supporting woodworking businesses in Melbourne, regional Victoria and across Australia.
How to Help Prevent Motor Overheating
Regular maintenance can help identify conditions that contribute to motor overload and unexpected downtime.
Keep the Machine Clean
Remove dust and production debris according to the approved cleaning procedure. Keep accessible ventilation openings clear.
Maintain Mechanical Components
Follow the maintenance schedule for applicable bearings, belts, pulleys and other driven components. Investigate unusual noise or resistance promptly.
Monitor Machine Performance
Watch for repeated alarms, vibration, unusual sounds or reduced performance. Do not ignore changes in the machine's normal operating behaviour.
Arrange Regular Servicing
Preventative maintenance can help identify developing mechanical, electrical and cooling problems before they interrupt production.
Need Help With ALARM-04?
If your NikMann edgebander continues to display ALARM-04, Forza Machinery can help assess the fault and discuss the appropriate service or troubleshooting options.
When contacting us, provide the machine model, the exact alarm message and the pressure-gauge reading if available.