ALARM: 00
Emergency stop - ON. |
Release emergency stops. |
ALARM: 01
Overloading frequency inverter. Possible overheating on one of the frequency motors. |
- Turn OFF the machine main power switch. - Wait about 30 seconds. - Turn ON the machine. |
ALARM: 02
Any of the induction motors is overheated. |
- Wait until the overheated motor cools down to normal working temperature. |
ALARM: 03
The door of machine is open. |
- Close the door. |
ALARM: 04
The compressed air system pressure is lower than 0.5 MPa. |
- Provide normal working pressure of 0.6 MPa. |
ALARM: 05
Second work piece is fed before the enabling signal by the light indicator lamp at the machine inlet. |
- Remove both work pieces and then switch the machine off using the main switch and wait for approximately 20 seconds and then switch the machine on again. |
ALARM: 06
In the initial initialization rounding unit is not detected by any sensors. |
- To be removed alarm is necessary unit to be initialized manually (by manually movements it). - Manual initialization can be done in the air off. |
ALARM: 06
Rounding unit has failed to crawl detail timely and has reached the end of the horizontal move. |
- It is the part to be removed manually from the feed. The alarm will automatically disappear 30 seconds after its appearance. |
ALARM: 07
The capacitive sensor B1 is not included. |
- Check that the sensor works. - Turn on the machine and press the Emergency Stop. - Place your finger on the sensor, if OK LED on the sensor should light. - Once you remove your finger should go off. - The distance between the work piece and the sensor B1 is very large. - Adjust the distance between the work piece and the sensor about 1 mm |
PHASE ALARM
Poor quality of the supply voltage (too low, too high or asymmetry phase). |
- Check that there is no break or loose connection in the power supply. - The machine cannot be powered properly, R S T the phases are reversed. |